SF
SF
Features
1. The cooling water jacket ensures water flows between the reach and barrel, creating an excellent cooling effect, reducing the minimum operating water level, and
increasing the pumpable water level.
2. Dry motor design, full cast iron motor casing with dual SiC mechanical shaft seals, excellent waterproof structure, and long service life.
3. A high-chromium (HCR) agitator at the bottom of the pump creates a powerful agitating current when activated, lifting the sediment and discharging it.
Construction bridges,
- Rivers,
- Gravel and concrete fields,
- Civil engineering,
- Basement drainage,
- Sewage sludge extraction
Model | Phase | Pole | Rated Speed (RPM) | INS.CLASS | MAX.AMB | Rated Voltage | Rated Output | Outlet | Rated Head | Rated Flow | Max Head | Max Flow | Rated Current | Pass Solid | Weight | ||
HP | Kw | inch | mm | M | m³/min | M | m³/min | Amp | mm | kg | |||||||
SF-337 | 3 | 4 | 1450/1750 | F | 40℃ | 220V-575V | 5 | 3.7 | 3" | 80 | 15 | 0.5 | 17 | 1.6 | 8.7 | 30 | 98 |
SF-437 | 3 | 4 | 1450 | F | 40℃ | 220V-575V | 5 | 3.7 | 4" | 100 | 10 | 1.0 | 17 | 1.6 | 8.7 | 30 | 98 |
SF-455 | 3 | 4 | 1450 | F | 40℃ | 220V-575V | 7½ | 5.5 | 4" | 100 | 12 | 1.3 | 19 | 2.0 | 12.3 | 30 | 116 |
SF-411 | 3 | 4 | 1450 | F | 40℃ | 220V-575V | 15 | 11 | 4" | 100 | 25 | 1.9 | 31 | 3.0 | 26.0 | 35 | 198 |
SF-611 | 3 | 4 | 1450 | F | 40℃ | 220V-575V | 15 | 11 | 6" | 150 | 15 | 2.0 | 22 | 4.0 | 26.0 | 35 | 194 |